Quantifying the effect of wind turbines on lightning location and characteristics
作者: Soula S.; Georgis J.-F.; Salaün D.
刊名: Atmospheric Research
ISSN: 1698095
出版年: 2019
卷: 221
起始页码: 98
结束页码: 110
语种: 英语
Scopus关键词: Lightning ; Storms ; Annual distributions ; Cumulative number ; Lightning location ; Lightning strokes ; Peak currents ; Rate of increase ; Three categories ; Winter storms ; Wind turbines ; annual variation ; cloud to ground lightning ; spatial distribution ; storm ; wind turbine ; France
英文摘要: This study shows and quantifies the effect of the presence of wind turbines on lightning stroke location, density, polarity, peak current and annual distribution in areas where they are installed. We analyze the CG lightning activity recorded by Météorage during 21 years (1995–2015) over a 0.5° × 0.5° area in southwestern France (2.5°E-3°E; 44°N-44.5°N). The study area includes 8 farms with 2 to 29 turbines each, most of them installed between 2007 and 2010. The results show that the rate of increase of the cumulative number and the proportion of CG strokes are significantly larger around the turbines when they are installed, e.g. ~ 4.7 and 3.4 times, respectively, in a radius of 100 m. The proportion of positive CG strokes is lower around the turbines, e.g. ~ 3 times in a radius of 200 m. The annual distribution of CG strokes around the turbines is very different from that of the whole study area, with a total proportion of 36.9% and 2.3% in winter, respectively. Case studies of daily winter storm activity show that up to 93% of the strokes detected in the study area are located in the vicinity of wind turbines. The strokes are classified in three categories: first strokes of CG flashes (~31%), subsequent strokes of CG flashes (42%) and upward self-initiated discharges produced after a previous flash in the surrounding area (~27%). © 2019
Citation statistics:
资源类型: 期刊论文
标识符: http://119.78.100.158/handle/2HF3EXSE/122286
Appears in Collections:气候变化事实与影响

Files in This Item:

There are no files associated with this item.


作者单位: University of Toulouse/CNRS, Laboratory of Aerology, 14 avenue Edouard Belin, Toulouse, 31400, France

Recommended Citation:
Soula S.,Georgis J.-F.,Salaün D.. Quantifying the effect of wind turbines on lightning location and characteristics[J]. Atmospheric Research,2019-01-01,221
Service
Recommend this item
Sava as my favorate item
Show this item's statistics
Export Endnote File
Google Scholar
Similar articles in Google Scholar
[Soula S.]'s Articles
[Georgis J.-F.]'s Articles
[Salaün D.]'s Articles
百度学术
Similar articles in Baidu Scholar
[Soula S.]'s Articles
[Georgis J.-F.]'s Articles
[Salaün D.]'s Articles
CSDL cross search
Similar articles in CSDL Cross Search
[Soula S.]‘s Articles
[Georgis J.-F.]‘s Articles
[Salaün D.]‘s Articles
Related Copyright Policies
Null
收藏/分享
所有评论 (0)
暂无评论
 

Items in IR are protected by copyright, with all rights reserved, unless otherwise indicated.