globalchange  > 气候变化事实与影响
DOI: 10.1016/j.applthermaleng.2019.02.047
WOS记录号: WOS:000465058700070
论文题名:
Thermodynamic analysis of low GWP alternatives to HFC-245fa in high-temperature heat pumps: HCFO-1224yd(Z), HCFO-1233zd(E) and HFO-1336mzz(Z)
作者: Mateu-Royo, Carlos; Navarro-Esbri, Joaquin; Mota-Babiloni, Adrian; Amat-Albuixech, Marta; Moles, Francisco
通讯作者: Mateu-Royo, Carlos
刊名: APPLIED THERMAL ENGINEERING
ISSN: 1359-4311
出版年: 2019
卷: 152, 页码:762-777
语种: 英语
英文关键词: Low-grade waste heat recovery ; HTHP ; Liquid-to-suction heat exchanger ; Energy efficiency ; Vapour compression system ; Climate change mitigation
WOS关键词: REFRIGERANTS ; R1234ZE(E)
WOS学科分类: Thermodynamics ; Energy & Fuels ; Engineering, Mechanical ; Mechanics
WOS研究方向: Thermodynamics ; Energy & Fuels ; Engineering ; Mechanics
英文摘要:

This paper analyses the feasibility of HCFO-1224yd(Z), HCFO-1233zd(E) and HFO-1336mzz(Z), three low global warming potential (GWP) refrigerants, as alternatives to HFC-245fa in high-temperature heat pump (HTHP) systems for low-grade waste heat recovery. HTHPs are a sustainable technology that can help to mitigate climate change through the thermal valorisation of the industrial low-grade waste heat. Before presenting and analysing the results, mapping of the minimum superheat degree requirement in the operating range, and the influence of the Internal Heat Exchanger (IHX) on each alternative are studied. The simulations were carried out at condensing temperatures from 115 to 145 degrees C and evaporating temperatures from 45 to 75 degrees C, using a single-stage cycle with and without IHX. Finally, the Total Equivalent Warming Impact (TEWI) evaluation is performed to illustrate the environmental effect of each alternative. Attending to the results, HCFO-1233zd(E) improves the COP about 27% compared to HFC-245fa, whereas HFO-1336mzz(Z) and HCFO-1224yd(Z) show an improvement of approx. 21 and 17%, respectively. Although HCFO-1233zd(E) and HCFO-1224yd(Z) present similar suction volumetric flow rate to HFC-245fa, HFO-1336mzz(Z) shows a relative increment up to 80%, and therefore, higher compressor and installation size are expected for this refrigerant. Finally, the TEWI analysis presents a significant reduction of the equivalent CO2 emissions for each low GWP alternative, between 59 and 61%. HCFO-1233zd(E) shows the highest reduction in all the simulation cases, followed by HCFO-1224yd(Z) and HFO-1336mzz(Z).


Citation statistics:
资源类型: 期刊论文
标识符: http://119.78.100.158/handle/2HF3EXSE/133038
Appears in Collections:气候变化事实与影响

Files in This Item:

There are no files associated with this item.


作者单位: Univ Jaume 1, Dept Mech Engn & Construct, ISTENER Res Grp, Campus Riu Sec S-N, E-12071 Castellon de La Plana, Spain

Recommended Citation:
Mateu-Royo, Carlos,Navarro-Esbri, Joaquin,Mota-Babiloni, Adrian,et al. Thermodynamic analysis of low GWP alternatives to HFC-245fa in high-temperature heat pumps: HCFO-1224yd(Z), HCFO-1233zd(E) and HFO-1336mzz(Z)[J]. APPLIED THERMAL ENGINEERING,2019-01-01,152:762-777
Service
Recommend this item
Sava as my favorate item
Show this item's statistics
Export Endnote File
Google Scholar
Similar articles in Google Scholar
[Mateu-Royo, Carlos]'s Articles
[Navarro-Esbri, Joaquin]'s Articles
[Mota-Babiloni, Adrian]'s Articles
百度学术
Similar articles in Baidu Scholar
[Mateu-Royo, Carlos]'s Articles
[Navarro-Esbri, Joaquin]'s Articles
[Mota-Babiloni, Adrian]'s Articles
CSDL cross search
Similar articles in CSDL Cross Search
[Mateu-Royo, Carlos]‘s Articles
[Navarro-Esbri, Joaquin]‘s Articles
[Mota-Babiloni, Adrian]‘s Articles
Related Copyright Policies
Null
收藏/分享
所有评论 (0)
暂无评论
 

Items in IR are protected by copyright, with all rights reserved, unless otherwise indicated.