globalchange  > 全球变化的国际研究计划
DOI: 10.1007/s12325-019-01028-y
WOS记录号: WOS:000481415900024
论文题名:
Reduced Environmental Impact of the Reusable Respimat (R) Soft Mist (TM) Inhaler Compared with Pressurised Metered-Dose Inhalers
作者: Hansel, Michaela2; Bambach, Thomas1; Wachtel, Herbert3
通讯作者: Bambach, Thomas
刊名: ADVANCES IN THERAPY
ISSN: 0741-238X
EISSN: 1865-8652
出版年: 2019
卷: 36, 期:9, 页码:2487-2492
语种: 英语
英文关键词: Product carbon footprint ; Pulmonary ; Respimat ; Reusable ; Soft mist inhaler
WOS学科分类: Medicine, Research & Experimental ; Pharmacology & Pharmacy
WOS研究方向: Research & Experimental Medicine ; Pharmacology & Pharmacy
英文摘要:

Introduction: Pressurised metered-dose inhalers (pMDIs) are associated with global warming potential values as they contain a hydrofluoroalkane (HFA) propellant, whereas the Respimat (R) Soft Mist (TM) inhaler is propellant-free. The original disposable Respimat has recently been updated to provide a reusable device that is similar in performance and use but is more convenient to patients and reduces environmental impact. This study compared the product carbon footprint (PCF) of Respimat (both disposable and reusable) and pMDIs to understand life cycle hotspots, and also to determine the potential quantitative environmental benefits of a reusable Respimat product. Methods: PCFs of four inhalation products-tiotropium bromide (Spiriva (R)) Respimat, ipratropium bromide/fenoterol hydrobromide (Berodual (R)) Respimat, Berodual HFA pMDI and ipratropium bromide (Atrovent (R)) HFA pMDI-were assessed across their whole life cycle. Results Data show that Respimat inhalers have a lower PCF (carbon dioxide equivalent per kilogram) than HFA pMDIs: pMDI Atrovent 14.59; pMDI Berodual 16.48; disposable Spiriva Respimat 0.78; disposable Berodual Respimat 0.78. Approximately 98% of the pMDI life cycle total is due to HFA propellant emissions during use and end-of-life phases. The impact of the material used for the Respimat product outweighs the impact of the material used to make the empty cartridge. Furthermore, compared with the single-use device over 1 month, the PCF of Spiriva Respimat was further reduced by 57% and 71% using the device with refill cartridges over 3 and 6 months, respectively. Conclusion: Together, these data suggest that Respimat inhalers, and in particular the new reusable inhaler, can reduce the environmental impact associated with inhaler use. Funding Boehringer Ingelheim.


Citation statistics:
被引频次[WOS]:29   [查看WOS记录]     [查看WOS中相关记录]
资源类型: 期刊论文
标识符: http://119.78.100.158/handle/2HF3EXSE/146152
Appears in Collections:全球变化的国际研究计划

Files in This Item:

There are no files associated with this item.


作者单位: 1.Boehringer Ingelheim Int GmbH, Ingelheim, Germany
2.CSL Behring GmbH, Marburg, Germany
3.Boehringer Ingelheim Pharma GmbH & Co KG, Ingelheim, Germany

Recommended Citation:
Hansel, Michaela,Bambach, Thomas,Wachtel, Herbert. Reduced Environmental Impact of the Reusable Respimat (R) Soft Mist (TM) Inhaler Compared with Pressurised Metered-Dose Inhalers[J]. ADVANCES IN THERAPY,2019-01-01,36(9):2487-2492
Service
Recommend this item
Sava as my favorate item
Show this item's statistics
Export Endnote File
Google Scholar
Similar articles in Google Scholar
[Hansel, Michaela]'s Articles
[Bambach, Thomas]'s Articles
[Wachtel, Herbert]'s Articles
百度学术
Similar articles in Baidu Scholar
[Hansel, Michaela]'s Articles
[Bambach, Thomas]'s Articles
[Wachtel, Herbert]'s Articles
CSDL cross search
Similar articles in CSDL Cross Search
[Hansel, Michaela]‘s Articles
[Bambach, Thomas]‘s Articles
[Wachtel, Herbert]‘s Articles
Related Copyright Policies
Null
收藏/分享
所有评论 (0)
暂无评论
 

Items in IR are protected by copyright, with all rights reserved, unless otherwise indicated.