globalchange  > 气候变化事实与影响
DOI: 10.1016/j.atmosenv.2015.05.039
Scopus记录号: 2-s2.0-84938066926
论文题名:
Calibration of PM<inf>2.5</inf> mass concentrations used in the Pittsburgh Aerosol Research and Inhalation Epidemiology Study
作者: Bilonick R; A; , Connell D; P; , Talbott E; O; , Xue T; , Rager J; R
刊名: Atmospheric Environment
ISSN: 0168-2563
EISSN: 1573-515X
出版年: 2015
卷: 115
起始页码: 325
结束页码: 339
语种: 英语
英文关键词: Federal Reference Method ; Filter samplers ; Fine particulate matter ; Structural equation model ; TEOM
Scopus关键词: Behavioral research ; Calibration ; Diseases ; Errors ; Measurement errors ; Nonlinear equations ; Particles (particulate matter) ; Regression analysis ; Systematic errors ; Telecommunication services ; Federal reference methods ; Filter samplers ; Fine particulate matter ; Structural equation modeling ; TEOM ; Random errors ; aerosol property ; calibration ; concentration (composition) ; error analysis ; estimation method ; nonlinearity ; particle size ; regression analysis ; speciation (chemistry) ; Article ; calibration ; low temperature ; measurement error ; particulate matter ; priority journal ; random error ; systematic error ; temperature ; temperature sensitivity ; United States ; Pennsylvania ; Pittsburgh ; United States
Scopus学科分类: Environmental Science: Water Science and Technology ; Earth and Planetary Sciences: Earth-Surface Processes ; Environmental Science: Environmental Chemistry
英文摘要: Fifteen different types of PM2.5 mass concentration samplers were used by seven different monitoring networks at 47 locations in the Pittsburgh, Pennsylvania, region from 1999 to 2008. The samplers included Federal Reference Method (FRM) samplers, speciation samplers, tapered element oscillating microbalance (TEOM) samplers, and others. The different measurement principles used in these designs tended to lead to systematic differences (biases) when measuring the same quantity, and to differences in the typical size of random errors (imprecision) introduced by each type of sampler. Bias can take different forms either as a constant bias or as a non-constant (scale) bias, which depends on the size of the quantity being measured. The objective of the work presented here was to simultaneously calibrate the measurements made by these different samplers to remove relative biases (both constant and non-constant) so that all of the available PM2.5 data could be used interchangeably to develop exposure estimates for a retrospective epidemiology study. In order to accomplish this, we used linked temperature-stratified structural equation models, nonlinear regression models, and nonlinear mixed effects models. Applying these methods we constructed a comprehensive measurement error model that included both systematic error and random error components, and derived calibration equations that can be applied to place all of the PM2.5 mass concentration measurements on the same scale. The FRM sampler was used as the reference scale although the parameter estimates are invariant to this choice. Results showed that: (1) 50°C TEOM samplers tended to show a large downward bias relative to the FRM sampler at low temperatures, and the magnitude of this bias decreased according to a nonlinear (sigmoidal) pattern with increasing temperature, (2) speciation samplers and other integrated samplers generally showed smaller biases relative to the FRM sampler that were not temperature-dependent, and (3) FRM samplers tended to be more precise than non-FRM samplers. These results are consistent with our previous work focusing on just a single monitoring site. Results are also presented here for several types of samplers that were not part of our previous study, including 30°C TEOM, FDMS TEOM, and beta attenuation monitors. © 2015 Elsevier Ltd.
Citation statistics:
资源类型: 期刊论文
标识符: http://119.78.100.158/handle/2HF3EXSE/81671
Appears in Collections:气候变化事实与影响

Files in This Item:

There are no files associated with this item.


作者单位: University of Pittsburgh School of Medicine, Pittsburgh, PA, United States; CONSOL Energy Inc. Research and Development, South Park, PA, United States; University of Pittsburgh Graduate School of Public Health, Pittsburgh, PA, United States

Recommended Citation:
Bilonick R,A,, Connell D,et al. Calibration of PM<inf>2.5</inf> mass concentrations used in the Pittsburgh Aerosol Research and Inhalation Epidemiology Study[J]. Atmospheric Environment,2015-01-01,115
Service
Recommend this item
Sava as my favorate item
Show this item's statistics
Export Endnote File
Google Scholar
Similar articles in Google Scholar
[Bilonick R]'s Articles
[A]'s Articles
[, Connell D]'s Articles
百度学术
Similar articles in Baidu Scholar
[Bilonick R]'s Articles
[A]'s Articles
[, Connell D]'s Articles
CSDL cross search
Similar articles in CSDL Cross Search
[Bilonick R]‘s Articles
[A]‘s Articles
[, Connell D]‘s Articles
Related Copyright Policies
Null
收藏/分享
所有评论 (0)
暂无评论
 

Items in IR are protected by copyright, with all rights reserved, unless otherwise indicated.