globalchange  > 影响、适应和脆弱性
项目编号: 1441636
项目名称:
NSF EAGER: Evaluation of the osteogenic benefits of low-intensity pulsed ultrasound and whole-body vibration in an in vivo rodent osseointegration model
作者: Ola Harrysson
承担单位: North Carolina State University
批准年: 2013
开始日期: 2014-08-15
结束日期: 2016-12-31
资助金额: USD185195
资助来源: US-NSF
项目类别: Standard Grant
国家: US
语种: 英语
特色学科分类: Engineering - Chemical, Bioengineering, Environmental, and Transport Systems
英文关键词: lmhf vibration ; oi ; research ; relative benefit ; bone ingrowth ; patient ; comparison ; rat ; low-intensity pulsed ultrasound ; transfemoral oi ; various vibration protocol ; rodent osseointegration modelbroader significance ; osteogenic benefit ; rodent model ; whole-body vibration ; dental implant ; understanding ; nsf eager ; potential benefit
英文摘要: PI: Harrysson, Ola L.
Proposal: 1441636
Title: NSF EAGER: Evaluation of the osteogenic benefits of low-intensity pulsed ultrasound and whole-body vibration in an in vivo rodent osseointegration model

Broader Significance & Importance
Some metal implants are placed into bones with the intent of becoming permanently connected. This process is named osseointegration (OI). OI generally takes several weeks and there is an advantage in achieving rapid and complete OI because it accelerated the rehabilitation and training of patients. Several strategies may be used to increase OI of metal implants. They have the advantage to be applied externally and be effective with brief periods of exposure (approx. 20 minutes per day). Little is known about the relative benefits of these modalities and about any potential benefits of combining these modalities.

Technical description
The goals of this research are to investigate an integrated system to promote bone ingrowth into transdermal OI implants. This includes the following aims: (1) Development and validation of a mechanical actuation system for delivery of controlled LMHF vibration with optimized strain and frequency to the pelvic limbs of rats through a pilot in vivo study in rats, (2) The comparison of the relative effectiveness of LMHF vibration (using the system developed in Objective 1) and commercial LIPUS alone and combined, through an in vivo study in rats, (3) As a secondary objective, the comparison of bone ingrowth and bone density assessment using dual-energy X-ray absorptiometry (DEXA) and micro-computed tomography (micro-CT), (4) As another secondary objective, the comparison of bone surface strains adjacent to an OI implant and acceleration of the implant, measured using an accelerometer.
The proposed research is motivated by the fact that OI is slow with some current implant designs. For example, the rehabilitation process after placement of a transfemoral OI implant by the Branemark group takes more than one year and requires two surgical procedures. This research will help evaluate the benefits of LMHF vibration and LIPUS alone and combined for implants with different designs in an in vivo rodent model. Upon successful completion, the proposed work will: (1) yield a better understanding of the bone surface strains generated through various vibration protocols, (2) lead to the development of a device allowing the local application of LMHF vibration, and (3) yield a better understanding of the relative benefit and synergy of LMHF vibration and LIPUS on bone ingrowth of threaded and textures implants. 332,000 total hip replacement and 719,000 total knee replacements are performed annually in the United States. This number is anticipated to grow in the foreseeable future. OI dental implants are a well-established medical procedure. One of the most common complications of dental implants is the lack of OI in patients with preexisting osteoporosis. Approximately 1.7 million people live with a missing limb in the United States and an estimated 185,000 amputations are performed each year. The number of individuals experiencing amputation is predicted to increase to more than 3.6 million by 2050. Lower limb amputees commonly use socket-type prostheses. These prostheses have several limitations: optimal fit is difficult to achieve causing undesirable stresses on tissues that can lead to pressure points, soft tissue sores, and nerve damage. Prostheses fixed by OI address many of the shortcomings resulting from the use of socket prostheses and their applications will most likely grow in the future. Patients fitted with a TOP instead of a socket prosthetics can live more active and healthy lives and more efficiently contribute to society. This research will further our understanding of strategies that may benefit individuals with OI joint prostheses, with dental implants, and with transdermal OI implants. By investigating non-invasive, user-friendly strategies that promote bone ingrowth, this research will benefit all patients receiving implants with the intent of OI.
资源类型: 项目
标识符: http://119.78.100.158/handle/2HF3EXSE/96021
Appears in Collections:影响、适应和脆弱性
气候减缓与适应

Files in This Item:

There are no files associated with this item.


Recommended Citation:
Ola Harrysson. NSF EAGER: Evaluation of the osteogenic benefits of low-intensity pulsed ultrasound and whole-body vibration in an in vivo rodent osseointegration model. 2013-01-01.
Service
Recommend this item
Sava as my favorate item
Show this item's statistics
Export Endnote File
Google Scholar
Similar articles in Google Scholar
[Ola Harrysson]'s Articles
百度学术
Similar articles in Baidu Scholar
[Ola Harrysson]'s Articles
CSDL cross search
Similar articles in CSDL Cross Search
[Ola Harrysson]‘s Articles
Related Copyright Policies
Null
收藏/分享
所有评论 (0)
暂无评论
 

Items in IR are protected by copyright, with all rights reserved, unless otherwise indicated.